fbpx skip to Main Content
Evaporative Air Conditioner

Evaporative Air Conditioner
Directions for Use
Foreword
Thanks for your trust and support to choose Evaporative Air Conditioner. Please read the directions carefully in order to help you use our products…
Theory of temperature drop
Evaporative Air Conditioner is the high –tech product researched and developed by company. This conditioner use the theory of evaporation cooling, by using the Water Curtain and Fan as the evaporator, the conditioner can make the temperature drop effectively and improve the quality of air as it filters the dusts in the air. The theory is: the draught fan does a suction to make a sub-pressure, as the same time the pump carries the water to the distribution instrument to fully moist the surface of the water curtain, and the special angle of the water curtain pressures the water directly to the Intel side. The hot air passes the wet curtain, and absorbs the heat in the in the air and then makes the temperature come down. The air filters in the curtain, then become fresh and cool, and, the unevaporated water drop to the base plate to make a loop.

Products List
1: one mainframe
2: one remote controller
3: the Book of Instructions (including one service card)
Controlling system and remote controller
Electric power
1: key switch
Switch on the electric power, press key switch to open the conditioner, Acquiescent as the state of cooling at the first time, and will repeat last state when open again. Press this key switch at any state to stop working.
2: Cooling
Press this pattern to enter the cooling state. Acquiescent as the Low Speed Wind
3: Wind speed:
Press to set the speed which is divided into high/middle/low, the wind speed pattern will be changed correspondingly.
4. Direction of WIND:
Control the directional; swing, press again to stop swinging.
5. Types of Wind:
Change among the standard wind, the natural wind and the sleep wind.
Standard wind: settle a wind speed which won’t change.
Natural Wind: The wind speed will change automatically and randomly.
Sleep Wind: Turn of middle speed half an hour later when switched from the high speed, turn to low speed half an hour later when switched from the middle speed, and no change from low speed to this state.
Health and Fresh
6. Negative ion:
Press to release negative ion. As the same time the pattern lights.
7. Definite time:
Press to use the time function, the pattern lights, chose the definite time as you want according to time displayed. When turned to 9h, Press to close the timing service.
#Others:
1. Sounds :
Buzzer when pressed. The remote controller is same with the LCD Panel
2. Protection for lacking of water.
Flashing when the water is lower than the regular line, and the pump would stop working; back to work if water is added.

To operate your unit

1: get the conditioner out of the package.
2. Add water (1) open the filler (press to open), observe when fill water. Tips for filling water:
* avoid damaging the electric parts by water
* Max enough, or the water will overflow
*do use clean water
(2) DIRECTLY FROM THE CONNECTED OUTLET AT THE ACCESS TO TAP WATER (SUCH AS DO NOT OFTEN MOVE THE AIR COOLER, IT IS RECOMMENDED TO USE THIS METHOD TO ADD WATER0, AS SHOWN:
3. switch on to get to the holding state, press the key switch again, set different modes according to your needs: wind speed, direction of wind, negative ion, types of wind and the timer.
4. Press the keys witch to stop the running state and back to the holding state.
5. you can use the remote controller to operate the air conditioner, the function of remote controller is the same with the LCD screen.
(1) Remove the back cover to insert batteries and check the indicator
(2) When the remote controller pointing toward the air conditioner unit within 10m, signal is sent
(3 put the remote controller into the position on the top of the unit to avoid its falling.
To operate your unit properly
Please read carefully how to operate the unit properly. We shall not hold the responsibility if the accident appears unexpectedly .
1. The water level must not exceed the MAX level at any time or lower than the MIN level while cooling.
2. When the ambient humidity is high, normal temperature is recommended in that cooling mode also means moistening.
3. When added water to the unit, do not slant or hit in order to avoid over brimming and never overturn the unit.
4. Do not put anything on the unit or cover the air-out place, no obstacle within one meter during work.
5. The pump won’t work if the function of cooling is required while there is no water in the tank.
6. Cut the electrical source and unplug the line before checking or cleaning.
7. When cleaning the surface, use a wet packing sheet, do not use detergent that would corrode the unit and do not rinse directly with water.
8. Unplug and re-start the unit before the unit is out of water when it is slanted with water in the tank.
9. The air outlet holes should be kept away from the wall and the curtain, or is would block the way of air cause the failure of the effect.
10. Do not hit or shake the unit during working or it would automatic stop. Restart is if happened
11. Unplug the unit when not in the operation
12. Immediately contact with the distributor if the covering of power plug or code is broken
13. Remote controller handling procedure:
(1) Attention to the +/- marks
(2) Better not throw out cells for the environmental protection
(3) Remove cells when the remote controller is not used for a long period.
14. Directions and help should be given to weak, lag, child when they are using the unit
15. Keep the children away from playing the unit

Cleaning
*the filter:
Unplug, turn off the bolts of the filter, and press the buckle to get off the filter, use soapy water and banister brush to clean the filter then dry in the sun and reinstall the air filter.
*water curtain:
Unplug and take off the filter to get the curtain out, use water to clean and reinstall the curtain. Attention: hydraulic pressure cannot be high, and do not use the following goods: paint thinner, benzene and polishing agents. Etc.
*Tank:
Turn off the power switch, get the end cap, discharge the water and fill clean water.
Advice: change clean water every day; do not wait for the water become smelly.